Search Results for "Error"
There were 57 articles found for your query: (Page 1 of 3)     «« |  Prev | 1 | 2 | 3 | Next | »»
  1. No GPS Found with Field Scout TDR MeterNo GPS Found with Field Scout TDR Meter [Article]


  2. Meter prematurely gives "READING COMPLETE" message.Meter prematurely gives "READING COMPLETE" message. [Article]
    ...the meter is being withdrawn from the soil. This is similar to second part of solution for !! Depth Error !! error mes

  3. !Error- Too Fast! message!Error- Too Fast! message [Article]
    Probe is being inserted too quickly. If the meter is inserted faster than 1 inch per 1 second, the ASABE standard states that the reading s

  4. !! Depth Error !! message!! Depth Error !! message [Article]
    This error message indicates that the meter missed a depth reading. This can happen when: a) The speed of insertion exceeds the meter's abilit

  5. EXCESSIVE FORCE errorEXCESSIVE FORCE error [Article]
    Load cell cannot support more than 250lb without permanent damage. Move a few feet away to another measuring spot and try again.

  6. Error Message "Unable to connect to the Logger. Overflow"Error Message "Unable to connect to the Logger. Overflow" [Article]
    The "Overflow" error message indicates that there is some bug in the SpecWare. Reinitializing the logger header will probably fix the problem (see attached file). If there is data that

  7. Error Message "Run-time error 63: bad record number" (SPAD 502 meter)Error Message "Run-time error 63: bad record number" (SPAD 502 meter) [Article]
    If the SPAD meter is turned off and immediately turned back on, a capacitor in the data logger's microcontroller circuit will not have time to completely power down.&nb

  8. Getting E07 when trying to calibrate the IQ 150 (2162)Getting E07 when trying to calibrate the IQ 150 (2162) [Article]
    The probe has failed and needs to be replaced. This error code is not related to the chassis.

  9. Error Message "Bad Data Returned X[72]"Error Message "Bad Data Returned X[72]" [Article]
    This message appears if the paperclip test is done with the interface cable connected to a logger or weather station. This very likely indicates that the correct Com port has been selected. Remove t

  10. Error Message "Division by zero"Error Message "Division by zero" [Article]
    The "Division by Zero" error message can appear if there are too many files in the Specware directory (or the dire

  11. Getting a "Sensor Error" message when connecting the barometric pressure sensor to a weather station.Getting a "Sensor Error" message when connecting the barometric pressu... [Article]
    The weather station should be running firmware version 7.0 or greater. The firmware version can be seen in the uppper right corner of the Launch Options

  12. Error Message "Unable to Write WatchDog Header"Error Message "Unable to Write WatchDog Header" [Article]


  13. Error Message: Cannot relaunch Shuttle until all data has been downloadedError Message: Cannot relaunch Shuttle until all data has been downloaded [Article]
    The shuttle can only be launched when the LCD screen reads "off". This indicates that there is no data on the shuttle that has not been downloaded. If there are shuttle positions that have not yet b

  14. Error Message: The registration information for SpecWare has been tampered with (1). Please contact your distributor for assistanceError Message: The registration information for SpecWare has been tampered with ... [Article]
    This message is usually triggered when the installation date of the software precedes the date on the computer. Check that the date and time on your computer are correct. If this does not correct th

  15. Error Message: Cannot Find File olch2x32.ocx, file not registered Error Message: Cannot Find File olch2x32.ocx, file not registered [Article]
    When SpecWare is installed, several files are created or modified in the Windows sub-directory. If the software did not install properly, one or more of these files may not be present. Also, if the

  16. Error Message: No Carrier Found Error Message: No Carrier Found [Article]
    The telephone modem at the weather station has answered but cannot establish a synchronous connection with the computer modem. One possible cause is that the baud

  17. Error Message: SpecWare trying to perform a Fast LaunchError Message: SpecWare trying to perform a Fast Launch [Article]
    When communicating with remotely located WatchDog weather stations via radio transceivers or a telephone connection, it is not possible to bring up the Launch Options screen to modify th

  18. No GPS Found with Field Scout MeterNo GPS Found with Field Scout Meter [Article]


  19. Error Message 519  Unable to Contact WatchDog 2Error Message 519 Unable to Contact WatchDog 2 [Article]
    This message occurs when trying to use the 2000 Series Shuttle with version 1.06 and earlier of Spec8Pro. Update your Spec8Pro software.

  20. My model 450, 250, or 150 logger shows 20.7% humidity in errorMy model 450, 250, or 150 logger shows 20.7% humidity in error [Article]
    The RH sensor has two leads (wires) which are inserted into small sockets on the circuit board of the 450.